OPERATING THE DIESEL GENERATOR
warm down. Stopping the diesel engine suddenly may raise the temperature of
the engine abnormally and lock the nozzle and damage the diesel engine.
3. Turn electronic key to the OFF position to stop the genset. In the same way,
you can press the OFF button in remote starter key to stop the genset.
4. If do not use generator for a long time, please shut off fuel valve and then
make sure that both intake and exhaust valves are closed for avoiding engine
rusting. Pull slowly on the recoil handle until you feel resistance when the
piston of engine is in the compression stroke where both intake and exhaust
valves are closed.
NOTE
I. If you cannot stop the engine with a load on it then remove 'the load first
than stop the engine. -
Speed handle
19
3. If equipped with an electric starter, turn the electronic key
,
to the "OFF"
position.
4. Put the fuel handle to the "STOP" position.
2. Press down on the brake handle.