TROUBLESHOOTING
No or little spray from injection pump
and nozzle
Disassemble the nozzle and adjust it
on the test table
The governor speed handle is not on
the position of "RUN"
Turn the governor handle to the
position of "RUN"
Oil lever is too low or oil is too dirty
The standard of lubricating oil is
between upper line "H" and bottom
line "L"
Change oil if necessary
Recoil starter is not swift and powerful
enough
Start the engine according to "Start
Operation Procedure"
Ambient temperature is very low
No electricity of storage battery
Charge up or change the storage
battery
Solenoid is not energized or stuck
Check fuse, or replace solenoid
Electronic key or remote control unit
fails
Change the cell of remote starter key
4-2.3.2 Causes and troubleshooting for the generator not generating
electricity
Table13
Power switch is on the position of
'OFF"
Turn the switch handle to the position
of "ON"
Bad contact of the socket
Burned capacitance or capacitor
Change the capacitance or capacitor
Nuts loosened in volt meter
Voltage selector is burned
Carbon brush is snapped or worn off
Stator is short-circuited
Rotor Diode(s) is broken through