39
Jbus MODbus Description Display Attribute
Address Address Code
223 222 Tare calibration (“tARE”) W
Range:
0 = Disable calibration
1 = Enable calibration
224 223 Last calibration status R
Range:
0 = Idle
1 = calibration in progress
3 = calibration done without error
4 = calibration done with error
Notes: After reading, the word is set
to 0 if the value read is 3 or 4.
225 224 Peak reset W
Range:
0 = No operation
1 = Peak reset
226 225 Manual reset of alarm 1 condition W
Range:
0 = No operation
1 = Reset alarm 1
227 226 Manual reset of alarm 2 condition W
Range:
0 = No operation
1 = Reset alarm 2
228 227 Load default control parameters value W
Range:
0 = No operation
1 = Load default
Notes: Refer to device manual for listing
of default value.
45