EasyManua.ls Logo

Dynon Avionics EFIS-D6 - User Manual

Dynon Avionics EFIS-D6
50 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
EFIS-D6
Installation Guide
This product is not approved for installation in type certificated aircraft.
P/N 101209-000, Revision A
For use with firmware version 1.0
May, 2009
Copyright © 2003-2009 by Dynon Avionics, Inc.
Question and Answer IconNeed help?

Do you have a question about the Dynon Avionics EFIS-D6 and is the answer not in the manual?

Summary

Introduction

About this Guide

Explains the manual's electronic features like hyperlinks and download availability.

Menu Descriptions

Defines the syntax used to describe menu navigation within the installation guide.

Warning

Crucial safety note regarding product servicing, user-serviceable parts, and warranty implications.

Wiring Overview

Recommended Wiring Practices

Guidelines for safe electrical connections, insulation, and preventing shorts to protect the instrument.

Power Requirements

Details the voltage range (10-30 Vdc) and typical/maximum power consumption of the EFIS-D6.

25-Pin Female EFIS Harness

Illustrates the pin assignments and wire color coding for the EFIS-D6's main connector.

Instrument Installation

Selecting a Remote Compass Module Location

Guidance on choosing an ideal, magnetically clean location for the EDC-D10A compass.

EDC-D10 A Communication Cable

Specifies the pin connections between the EFIS-D6 and the EDC-D10A compass module.

Power Inputs

Explains the primary and backup power sources for the EFIS-D6 unit.

EFIS Serial Harness

Details the serial port's usage for PC connectivity and GPS data input.

PC Connection for Firmware Updates

Instructions for connecting to a PC to perform firmware upgrades and manage checklists.

GPS Connection for Airspeed Failover

How to integrate a GPS for airspeed data backup in case of pitot system failure.

Altitude Encoder Wiring

Steps to connect the EFIS-D6 to a transponder for altitude data transmission.

Serial Altitude Formats

Outlines different serial data formats compatible with various transponders.

Audio Alert Output

Instructions for connecting the audio alert output for alarms like AOA and altitude.

Panel Location and Mounting

Provides guidance and options for physically installing the EFIS-D6 unit into an aircraft panel.

Connecting Static & Pitot Lines

Details on attaching pitot and static pressure lines to the EFIS-D6 unit.

EFIS Calibration and Configuration

Ensuring Proper Installation

Steps to verify correct physical and electrical installation before initial operation.

Setting Zero Pitch (In flight)

Procedure to calibrate the pitch attitude display to the aircraft's level flight attitude.

Compass Heading Calibration

Comprehensive guide to calibrating the magnetic heading indication system for accuracy.

Obtaining Magnetic Inclination and Intensity

Instructions for locating and inputting local magnetic field data for calibration purposes.

EDC-D10 A Heading Calibration (On Ground Only)

Step-by-step process for calibrating the remote compass module while the aircraft is on the ground.

EFIS-D6 (Internal) Heading Calibration (On Ground and in Flight)

Procedure for calibrating the internal compass, including specific in-flight maneuvers.

Configure Airspeed Color Thresholds

How to set color-coded thresholds for airspeed ranges on the EFIS-D6 display.

Appendix

Appendix A: Instructions for Continued Airworthiness

Information on periodic checks and maintenance to ensure the EFIS-D6's ongoing airworthiness.

Firmware Upgrade

Guide on how to update the EFIS-D6 software to gain new features and improvements.

Displayed Alert Messages

Explains various alert messages the EFIS-D6 may show and their corresponding end conditions.

Troubleshooting Guide

Lists common issues encountered with the EFIS-D6 and provides recommended solutions.

Instructions for Return

Procedures to follow when returning the EFIS-D6 unit for service or repair.

Appendix B: Dynon AOA;Pitot Installation and Calibration

Detailed guide for installing and calibrating the Dynon Angle of Attack/Pitot probe.

Heater Controller Wiring and Mounting

Instructions for correctly wiring and mounting the heater controller for the AOA/Pitot probe.

Heater Status Connection

How to connect the heater status indicator for the AOA/Pitot probe for operational feedback.

AOA;Pitot Probe Mounting

Guidelines for selecting an appropriate location and mounting the AOA/Pitot probe.

Plumbing

Instructions for routing and connecting the pitot and AOA plumbing lines from the probe.

Calibration

Steps for calibrating the Angle of Attack (AOA) sensor to ensure accurate readings.

Alarm Setup

Configuration of audible AOA alarms, including setting progressive alarms and minimum speeds.

Appendix C: Encoder Serial-to-Gray Code Converter Installation

Guide for installing the serial-to-gray code converter for transponder compatibility.

Step 1: Transponder Wiring

Details on wiring the encoder converter to the aircraft's Mode-C transponder.

Step 2: Connecting to the EFIS-D6

Instructions for connecting the encoder converter to the EFIS-D6 25-pin harness.

Step 3: EFIS-D6 Encoder Format

Setting the correct altitude encoder format for reliable communication with the transponder.

Appendix D: Replacing the EFIS-D6 Battery Pack

Step-by-step instructions for safely replacing the internal backup battery pack.

Appendix E: Upgrading EFIS-D6 to EFIS-D10 A

Information on the process and features available when upgrading the EFIS-D6 to EFIS-D10A.

Appendix F: Weights

Lists the weights of the EFIS-D6 and associated sensors for aircraft weight and balance considerations.

Appendix G: EFIS-D6 Specifications

Provides detailed technical specifications for the EFIS-D6 unit.

Dynon Avionics EFIS-D6 Specifications

Operating Environment IconOperating Environment
operating temperature range-30° to 50° C
voltage range10 - 30 Vdc
power consumption typical8 watts
power consumption maximum13 watts
Display IconDisplay
display typeAMLCD, TFT
display backlight450 nits
display size3.8” diagonal
display resolution320 x 240 color pixels
Weight IconWeight
EFIS-D6 weight0.709 kg
EFIS-D6 + battery weight0.879 kg
EFIS 25-pin wiring harness weight0.32 kg
EDC-D10A weight0.102 kg
EFIS OAT weight0.08 kg
Heated AOA/Pitot Probe & Heater Controller weight0.32 kg
Unheated AOA/Pitot Probe weight0.16 kg

Related product manuals