Dyson Airblade
TM
hand dryer
9
Refitting Fascia &
Access Panels
Attach the front fascia panel back
on by latching the top lip onto
the middle fascia first and then
pivoting the fascia cover
downward until flush.
Install the bottom left and right
tamper proof screws back into the
machine using the supplied tool.
Hanging unit
Hang the unit on the secured
mounting bracket as illustrated
in
Fig 10
.
Securetheunitthroughthe4holes
in the lower section of the unit,
illustrated in
Fig 11
.
Fig 10 Fig 11
Installation Procedures
Install the (2) tamper proof screws
back into the inner section of the
fascia panel.
Re-install the Access panel and
tamper proof screw.
Recommended minimum anchor
size of 0.25”
ENG
Step 3.
Terminal block connections:
120 volt unit:
SecuretheLine,Neutraland
Ground wires into the proper
terminal block locations.
Connecting to the
Electrical Supply
cont.
Fig 9
L N
120v MODEL