FLIGHT MANUAL BO 105 CB-5/CBS-5
EUROCOPTER
3 - 4
LBA APPROVED
Rev. 0
WARNING LIGHT INDICATIONS
BAT 70
Conditions/Indications
Battery overtemperature (above 70°C)
Procedure
D O N G R O U N D
1. Battery sw Off
2. Engines Shut down
CAUTION BATTERY MUST BE INSPECTED OR REPLACED PRIOR TO NEXT
FLIGHT.
D I N F L I G H T
1. Battery sw Off
2. LAND AS SOON AS POSSIBLE
After landing:
3. Engines Leave running in idle
4. Collective lever and cyclic stick Lock
NOTE Continue flight only if visual inspection reveals no indication of battery overheating.
Leave battery off or disconnect battery.
CAUTION BATTERY MUST BE INSPECTED OR REPLACED AT DESTINATION
PRIOR TO NEXT FLIGHT.