• If the hob is installed above an oven, the oven has a built-in cooling
fan.
• The installation will comply with all clearance requirements and
applicable standards and regulations.
• A suitable isolating switch providing full disconnection from the mains
power supply is incorporated in the permanent wiring, mounted and
positioned to comply with the local wiring rules and regulations.
• The isolating switch must be of an approved type and provide a 3 mm
air gap contact separation in all poles (or in all active [phase] conductors
if the local wiring rules allow for this variation of the requirements).
• The isolating switch will be easily accessible to the customer with the
hob
installed.
• You consult local building authorities and by-laws if in doubt regarding
installation.
• You use heat-resistant and easy-to-clean finishes (such as ceramic
tiles) for the wall surfaces surrounding the hob.
9.3 After installing the hob, make sure that
• The power supply cable is not accessible through cupboard doors or
drawers.
• There is adequate flow of fresh air from outside the cabinetry to the base
of the hob.
• If the hob is installed above a drawer or cupboard space, a thermal
protection barrier
is installed below the base of the hob.
• The isolating switch is easily accessible by the customer.
9.4 Before locating the fixing brackets
The unit should be placed on a stable, smooth surface (use the packaging).
Do not apply force onto the controls protruding from the hob.
9.5 Adjusting the bracket position
Fix the hob on the work surface by screw 2 brackets on the bottom of
hob(see picture)
after installation.