Do you have a question about the East EA610 and is the answer not in the manual?
Output Waveform | Simulated Sine Wave |
---|---|
Input Voltage | 230V |
Output Frequency | 50/60Hz |
Protection | Overload, Overcharge |
Outlets | 4 x IEC |
Communication Interface | USB |
Operating Temperature | 0°C to 40°C |
General safety guidelines for using the UPS, including reading manual and charging.
Specifies environments and conditions to avoid for safe UPS operation and longevity.
Covers fire extinguisher use, socket placement, and safe handling of electrical components.
Critical instruction on the necessity of reliable grounding for the UPS equipment.
Steps for unpacking the UPS, verifying accessories, and checking for shipping damage.
Visual guide to identify components on the UPS front panel.
Visual guide to identify components on the UPS rear panel.
General instructions for installing the UPS, including placement and connections.
Key points to consider during UPS installation for optimal performance and safety.
Specific guidelines for safely installing batteries in extended runtime UPS models.
Explains the function of each key on the UPS control panel for operation and settings.
Details the meaning and behavior of the UPS status LED indicators.
Describes the information and graphics shown on the UPS LCD display.
Procedures for starting the UPS, both with utility power and battery power.
Procedures for shutting down the UPS safely, with and without utility power.
How to configure the UPS output voltage via the control panel.
How to set the UPS output frequency (50Hz or 60Hz) through the panel.
Setting the boost charge voltage for the UPS battery.
Setting the floating charge voltage for the UPS battery.
Configuring the voltage level at which the UPS will shut down to protect the battery.
Adjusting the current used for charging the UPS battery.
How to enable or disable the UPS shutdown when there is no load.
Configuring the power saving mode for the UPS when it has no load.
Enabling or disabling the UPS's ability to start automatically from DC power.
Enabling or disabling the UPS's ability to start automatically from AC power.
Options for saving settings, exiting the configuration, or restoring factory defaults.
How to view UPS output voltage and frequency on the display.
How to view the connected load's Watt and VA values.
How to check the internal chassis temperature of the UPS.
How to view the input voltage and frequency from the utility power.
How to check the UPS battery voltage and capacity.
Recommended monthly inspections to ensure UPS reliability and long-term service.
Guidance on maintaining UPS batteries for optimal performance and longevity.