Eastron SDM220MBUS User Manual
Jiaxing Eastron Electronic Instruments Co.,Ltd. Tel: 0086-573-83698881 83698882 Fax: 0086-573-83698883
Address: No.1369 Chengnan Road, Jiaxing, Zhejiang, 314001, China. Web: www.eastron.com.cn Email: ssales@eastron.com.cn
- 1 -
SDM220-MBUS
Single-Phase Two Module DIN rail Meters
Measures kWh, Kvarh, KW, Kvar, KVA, PF, Hz, dmd, V, A, etc.
Bi-directional measurement IMP & EXP
Two pulse outputs
MBUS
Din rail mounting 36mm
100A direct connection
Better than Class 1 / B accuracy
User Manual V1.8
2016
Question and Answer IconNeed help?

Do you have a question about the Eastron SDM220-MBUS and is the answer not in the manual?

Eastron SDM220-MBUS Specifications

General IconGeneral
Rated Voltage (Un)230V AC
Base Current (Ib)5A
AccuracyClass 1
DisplayLCD
Operating Temperature-25°C to +55°C
Storage Temperature-40°C to +70°C
WeightApprox. 0.2 kg
TypeSingle-phase energy meter
Communication ProtocolM-Bus
Frequency50/60Hz
Pulse Output1000 imp/kWh
MountingDIN rail (35mm)

Summary

PART 1 Specification

General Specifications

Lists electrical parameters such as voltage, current, frequency, power, and accuracy ratings for the meter.

Environment Specifications

Details operating and storage temperature, humidity, altitude, and installation category.

Output Specifications

Describes pulse output configuration and MBUS communication protocol details.

PART 2 Operation

Initialization Display

Explains the meter's initialization and self-checking process upon power-up.

Scroll Display by Button

Details how to navigate through displayed measurements using the scroll button.

Set-up Mode

Password Configuration

Instructions for entering the setup mode, including password confirmation.

Address ID Configuration

Details on setting the meter's Address ID, including default and range.

MBUS Secondary Address High Bit

Instructions for setting the high bit of the MBUS Secondary address.

MBUS Secondary Address Low Bit

Instructions for setting the low bit of the MBUS Secondary address.

Baud Rate Configuration

Details on configuring the baud rate for communication.

Parity Configuration

Instructions for setting the parity for communication.

Pulse Output Configuration

Details on configuring the pulse output options.

Pulse Constant Configuration

Details on configuring the pulse constant for outputs.

Pulse Duration Configuration

Instructions for setting the pulse duration for outputs.

Demand Integration Time

Details on setting the Demand Integration Time (DIT).

Automatic Scroll Time Interval

Instructions for setting the Automatic Scroll Time Interval.

Automatic Scroll Time Interval Configuration

Instructions for confirming the Automatic Scroll Time Interval setting.

Password Configuration Entry

Instructions for changing the password in setup mode.

Wiring and Dimensions

Wiring Diagram

Illustrates the terminal connections for pulse output and MBUS port.

Dimensions and Installation

Provides meter dimensions and shows DIN rail mounting details.

Related product manuals