Eastron SDM630 User Manual

Eastron SDM630
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
JIAXING EASTRON ELECTRONIC INSTRUMENTS
CO.,LTD.
TEL:0086-573-83698881 83698882 FAX: 0086-573-83698883
WEB: www.eastrongroup.com Email: sales@eastrongroup.com
Add: No.1369. Chengnan Road, Nanhu, Jiaxing, Zhejiang, China 314001.
- 1 -
SMART
SMART
SMART
SMART MINI
MINI
MINI
MINI POWER
POWER
POWER
POWER
SDM630
SDM630
SDM630
SDM630
USER
USER
USER
USER MANUAL
MANUAL
MANUAL
MANUAL
2012
2012
2012
2012 V1.1
V1.1
V1.1
V1.1
Question and Answer IconNeed help?

Do you have a question about the Eastron SDM630 and is the answer not in the manual?

Eastron SDM630 Specifications

General IconGeneral
ModelSDM630
CategoryMeasuring Instruments
Starting Current (Ist)0.4% Ib
Accuracy IECIEC 62053-22
Impulse Voltage6kV
DisplayLCD
MountingDIN Rail
Current InputThree-phase
Frequency50Hz, 60Hz
Frequency Range45-65Hz
Accuracy Class0.5S
Accuracy+/- 0.5%
Energy Measurement Range999999.99kWh
CommunicationModbus RTU
Communication InterfaceRS485
Operating Temperature-25°C ~ +55°C
Storage Temperature-40°C ~ +70°C

Summary

Introduction

Unit Characteristics

Details the parameters the SDM630 can measure and display, including voltage, frequency, and energy.

Current Transformer Primary Current

Explains the configuration range for CT primary current (1 to 9999A) for the unit.

RS485 Serial - Modbus RTU

Describes the use of the RS485 serial port with Modbus RTU protocol for remote monitoring.

Start Up Screens

Display Segments and Firmware Info

Covers the initial display segments check and firmware version display during startup.

Self-Test and Measurement Display

Details the unit's self-test procedure and its transition to active energy measurements.

Measurements

Voltage and Current

Displays phase-to-neutral voltages and current on each phase.

Frequency and Power factor and demand

Covers the display of frequency, total power factor, and individual phase power factors.

Power

Details the display of instantaneous power, power demand, and current demand.

Energy Measurements

Shows instantaneous active power, reactive power, volt-amps, and total energy values.

Setting Up

Set-up Menu Structure

Provides an overview of the menu structure and navigation for setup.

Set-up Entry Methods

Explains the methods for entering setup menus, selecting items, and confirming settings.

Number Entry Procedure

Details the step-by-step process for entering numerical values in setup screens.

Change Password

Guides the user through the process of changing the default password.

DIT Demand Integration Time

Configures the time period for integrating readings for maximum demand measurement.

Supply System

Allows setting the type of power supply being monitored (e.g., 1P2W, 3P3W, 3P4W).

CT Setting

Configures the primary and secondary current settings for external current transformers.

PT Setting

Sets the primary and secondary voltage values for the voltage transformer.

Pulse Output Configuration

Configures the pulse output for active or reactive energy measurement.

Pulse Rate and Duration

Sets the energy representation per pulse and the pulse width duration.

RS485 Address Configuration

Sets the unique address for the RS485 network.

Baud Rate Configuration

Configures the communication speed for the RS485 interface.

Parity Configuration

Sets the parity bit for RS485 communication error checking.

Stop Bits Configuration

Sets the number of stop bits for RS485 communication.

Clear Maximum Demand

Provides the function to reset maximum demand values for current and power.

Specifications

Measured Parameters

Lists the parameters the unit can monitor and display for different supply types.

Measured Inputs

Details the voltage and current input connectors and wire capacity.

Accuracy

Specifies the accuracy for voltage, current, frequency, power, and energy measurements.

Auxiliary Supply

Details the specifications for the auxiliary power supply connection.

Interfaces for External Monitoring

Describes the interfaces for external monitoring, including RS485 and pulse outputs.

Reference Conditions of Influence Quantities

Lists variables affecting measurement errors and their reference conditions.

Environment

Provides operating and storage temperature, humidity, and altitude specifications.

Mechanics

Details the physical dimensions, mounting, sealing, and material of the unit.

Case Dimensions

Installation

Three Phase Four Wire Wiring

Illustrates the wiring diagram for a three-phase, four-wire supply installation.

Three Phase Three Wires Wiring

Illustrates the wiring diagram for a three-phase, three-wire supply installation.

Related product manuals