38 EATON 620 Mobile Open Circuit Piston Pump Service Manual E-PUPI-TS018-E2 November 2017
Cold start manifold (Destroke)
Feedback sensor option
41
40
37
36
35
Torque
3.0 ± 0.2 Nm
Torque
3.0 ± 0.2 Nm
Torque
4.0 ± 0.4 Nm
Assembly torque values
Instructions
27
26
25
24
33
34
Torque
8.2 ± 0.8 Nm
47
20
45
4 X Torque
161 ± 16.0 Nm
4 X Torque
27 ± 2.7 Nm
46
Adjustable maximum stop option