VC 5000 11 ©Copyright Eaton Corp., 2019. All rights reserved.
Figure 10
2.5.5 Align the element air connections with the
passages in the spider and attach the element to
the spider with the appropriate fasteners. See Table
3. Make sure the element fully engages the register
in the spider.
WARNING
Use only the proper grade and number of
fasteners. Using commercial grade fasteners
(Grade 2) in place of Grade 8 fasteners may
result in failure of the fasteners under load,
causing personal injury or equipment damage.
TABLE 3
AIR CONNECTIONS FOR VC E
LEMENTS
SIZE AIR TUBE WASHER AIR TUBE WASHER
11.5VC500 201402 72 x 15 412178-02 412324-01
14VC500
201302 72 x 11 412178-03 412324-02
16VC600
20VC600
24VC650
201286 72 x 12 412178-05 412324-03
28VC650
33VC650
201284 72 x 13
412178-06
412324-04
37VC650 412178-08
42VC650
412178
-
06
14VC1000
201302
72 x 11 412178-03 412324-02 16VC1000 202408
20VC1000
201302
24VC1000
201286 72 x 12 412178-05 412324-03
32VC1000
38VC1200
201284
72 x 13
412178-06
412324-04
42VC1200
46VC1200
202081
412178
-
07
52VC1200 202751
72 x 14
412178-08
412324-05
51VC1600
304213
412178-09
60VC1600
412178
-
18
412324-06
66VC1600
412178-04 76VC1600
76VC2000