VC 5000 13 ©Copyright Eaton Corp., 2019. All rights reserved.
2.7.1.7 The final connection to the rotorseal MUST be
made with flexible hose and place no radial load
upon the rotorseal.
CAUTION
Do not use rigid pipe at the connection to the
rotorseal. Rigid piping will result in excessive
loads on the rotorseal bearings, shortening life.
CAUTION
Maximum applied air pressure is 125 psig (8.5
bar). Operation at pressures exceeding 125 psig
may result in damage to the element. Consult
the factory if operation at pressures greater
than 125 psig is desired.
Figure 12
TABLE 4
MAXIMUM SAFE OPERATING SPEEDS
Size (Narrow)
Maximum
RPM
Size (Narrow)
Maximum
RPM
Size (Wide)
Maximum
RPM
Size (Wide)
Maximum
RPM
11.5VC500
1800
28VC650
1000
14VC1000
1800
42VC1200
670
14VC500 1500 33VC650
900
16VC1000 1400 46VC1200 600
16VC600 1400 35VC650 20VC1000 1300 52VC1200
550
20VC600
1200
37VC650
800
24VC1000
1250
51VC1600
24VC650
1050
42VC650
28VC1000
110
0
60VC1600
520
32VC1000 1050 66VC1600 480
38VC1200
740
76VC1600
275