VC 5000 13 ©Copyright Eaton Corp., 2019. All rights reserved.
2.7.1.7 The final connection to the rotorseal MUST be
made with flexible hose and place no radial load
upon the rotorseal.
⚠
CAUTION
Do not use rigid pipe at the connection to the
rotorseal. Rigid piping will result in excessive
loads on the rotorseal bearings, shortening life.
⚠
CAUTION
Maximum applied air pressure is 125 psig (8.5
bar). Operation at pressures exceeding 125 psig
may result in damage to the element. Consult
the factory if operation at pressures greater
than 125 psig is desired.
Figure 12
TABLE 4
MAXIMUM SAFE OPERATING SPEEDS
Size (Narrow)
Maximum
Size (Narrow)
Maximum
Size (Wide)
Maximum
Size (Wide)
Maximum
14VC500 1500 33VC650
900
16VC1000 1400 46VC1200 600
16VC600 1400 35VC650 20VC1000 1300 52VC1200
550
800
32VC1000 1050 66VC1600 480
275