6. Filler and Drain Plugs
Remove filler plugs and check level of lubricant at specified intervals. Tighten
fill and drain plugs to proper torque specification.
7. Capscrews and Gaskets
Check all capscrews, especially those on PTO covers and rear bearing covers for
looseness which could cause oil leakage.
8. Gear Shift Lever Housing
Remove air lines at air valve. Remove the gear shift lever housing assembly
from the transmission.
Check the tension spring and washer for set and wear.
Check the gear shift lever spade pin and slot for wear.
Check bottom end of gear shift lever for wear and check slot of yokes and
blocks in shift bar housing for wear at contact points with shift lever.
General Inspection
During the lubricate intervals specified by the vehicle chassis manufacturer, check for
missing or loose transmission mounting capscrews that attach the transmission to the
engine.