Fit Securing Screw
When the PCB is in place, connect the wires from
the transformer to the 20Vac connector on the
PCB (11 in Figure 3).
Installing the Lid/Back Tamper
Figure
Lid/Back Tamper
Fit combined lid/back tamper bracket and switch
(provided). Ensure that the switch is oriented as
shown in Figure 25.
Connect the lead from the switch to the back
tamper connector on the PCB (see 2 in Figure 3).
Note that to be approved at Security Grade 3 you
must fit the lid/back tamper.
Step 2. Run Bus Cable
Please read “Cabling Requirements” on page 12.