Technical Specification i-on50EX/EXD
Page 38
EN50131-6 ratings
The i-on50EX/EXD provides space for one 17Ah
battery.
Under EN50131-6 for Security Grade 3
installations the required battery standby time is
60 hours. However, with an ATS4 communicator
fitted the requirement drops to 30 hours.
This means that all the devices powered by the
backup battery, including the control unit and at
least one keypad, should together draw no more
in total than an average of 570mA over a 30 hour
standby time. Note that for Security Grade 3 the i-
on50EX must use a plug-by communicator, which
may have its own power supply.
For Security Grade 2 the required battery standby
time is 12 hours. However, the total average
current available over 12 hours from the 17Ah
battery is limited by the power supply to 750mA.
(The current is limited to 750mA because when
mains is present the 1.5A power supply reserves
750mA to recharge batteries, leaving 750mA
available to supply the system.)
The table below shows the current consumption of
the control unit and each device that can be fitted
to it.
CIE power
requirement:
120mA min.
200mA max
i-kp01 power
requirement:
30mA (normal/idle)
45mA (backlight low)
65mA (backlight high)
KEY-
KPZ01/KP01/K01
power requirement
35mA backlight OFF,
internal prox reader only.
65mA max backlight ON,
external prox reader
connected
Wired Expander
requirement
20mA max quiescent.
300mA in alarm if
sounder connected.
Radio Expander
requirement
40mA max quiescent
320mA in alarm if
sounder connected.
Battery charging
requirement:
750mA per battery
(recharge to 80% within
24 hrs)
Plug-on
Communicator power
requirement:
i-sd02, i-dig02:
20mA quiescent
50mA max
Plug-on
Communicator power
requirement
i-gsm02:
150mA quiescent
and max.
Plug-by
Communicator pins
require:
3mA each when active.
10 FSL zones
20mA
5 four-wire CCL zones
30mA
12V Bus output
voltage range :
10±0.5V to 13.8V
12V Aux output
voltage range:
10±0.5V to 13.8V
12V Bell output
voltage range
10±0.5V to 13.8V
Max p-to-p ripple
voltage:
0.5V
Standby Battery:
12V, 17Ah sealed lead
acid (not supplied).
‘Low battery’ fault at:
< 12V
Aux power output fault
at:
< 9V
Deep discharge
protection at:
10±0.5V
Overvoltage protection
trigger voltage
15.8±1.0V
Standby time:
See “Power Availability”
on page 12.
Electromagnetic
Compatibility
Immunity
Conforms to EN50130-4.
Emissions
Conforms to EN61000-6-3.
Outputs
Panel: O/P 1
Voltage free, single pole relay
contacts rated 24VDC @ 1A.
Panel:
O/P 2 - 3
Open collector transistor,
+12VDC when inactive, 0V
when active. 500mA max.
Plug-by O/P 1-
16
Open collector transistor
+12VDC when inactive, 0V
when active, 50mA max.
LS 1
(loudspeaker)
Min impedance 16 Ohm per
output, current consumption =
280mA in alarm.
Expander:
Outputs
Open collector transistor,
+12VDC when inactive, 0V
when active. 500mA max.
Note: The current is limited by
the amount available from the
power supply driving the
expander.
KEY-KPZ01
Outputs
Open collector transistor,
+12VDC when inactive, 0V
when active, 500mA max.
Sounder Volume Levels (at 1m)
i-kp01 (at max volume)
70dB
Expander sounders
70dB
Expander 16 Ohm loudspeaker
93dB
Fuses
The control unit has a replaceable T250mA mains
fuse.
Electrical Safety
Conforms to EN60950-1.
Other
If you wish to connect the i-on50EX/EXD control
unit to a PC using either the Ethernet or the USB
port then make sure that the cables have the
following specifications: