NZM-XDMI-DPV1
(PROFIBUS-DPV1 Interface for
DMI)
144
11/04 MN01219002Z-EN
Format and meaning of the object data content
The following table displays the address location and the
meaning of the data content of the object. Furthermore, it
provides an example of how the data content can be
accessed by the application with the aid of the example
variable.
Table 31: Address location and meaning of the object data
content
All data contents with the exception of the serial number are
coded as ASCII strings.
Variable access
(example)
Data position Meaning
LS_identification.
Serial_number Octet 1 to 4 Serial number of the
circuit-breaker
Frame_size Octet 5 to 8 Frame size of the
circuit-breaker
NZM_type Octet 9 to 16 Circuit-breaker type
I
n
Octet 17 to 22 Rated current
Number_of_poles Octet 23 to 30 Number of poles of the
circuit-breaker
Current_transformer
Octet 31 to 40 Current transformer type
N_conductor_protection
Octet 41 to 62 Details about the neutral
pole protection
SW_Version
Octet 63 to 68 Firmware version of the
circuit-breaker
Module_Version Octet 69 to 80 Type and hardware version
of the plug-in module
type 0: no plug-in module
present
Module_SW_Version
Octet 81 to 86 Firmware version of the
plug-in module