Eaton W-VAC Series - Page 6

Eaton W-VAC Series
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
InstructionBook
Pa
g
e 6
IB131009EN

4-1 Type W-VAC Breaker Manual Operation (Single Tier Breaker Shown) .................................................. 23
5-1 Flush Mounted Configuration. ..................................................................................................................... 26
5-2 Behind the Door Configuration ................................................................................................................... 27
5-3 Closeup of Type W-VAC Breaker Vacuum Interrupters and Current Carrying System ........................... 27
5-4 a Type W-VAC 95 kV BIL Breaker Shown With Left Hand Cover Removed for Clarity Purposes ............. 28
5-4 b Type W-VAC 3150 Ampere Breaker Closeup of Completely Enclosed Pole Units ................................. 28
5-5 Closing Cam and Trip Linkage ................................................................................................................... 30
5-6 Charging Schematic .................................................................................................................................... 31
5-7 Typical DC and AC Control Schemes. ..................................................................................................... 34
5-8 Undervoltage Trip Device Configuration ..................................................................................................... 35
5-9 Closeup of Type W-VACW Breaker Vacuum Interrupters and Current Carrying System ....................... 36
6-1 Lubrication Points ........................................................................................................................................ 37
6-2 Vacuum Interrupter Showing Contact Erosion Indicator With Breaker Open .......................................... 40
6-3 Vacuum Interrupter Showing Contact Erosion Indicator With Breaker Closed ........................................ 40
6-4 Breaker Shown Closed and Interrupter Erosion Satisfactory (3150A). .................................................... 41
6-5 Breaker Shown Colsed and Interrupter Erosion Unsatisfactory (3150A). ................................................ 41
6-6 “T” Contact Wipe Indicator .......................................................................................................................... 42
6-7 Wipe Indication ............................................................................................................................................ 42
TABLES
Table
Title
Page
1.1 Type W-VAC and W-VACW Vacuum Circuit Breaker Ratings .................................................................... 1
1.2 Type W-VACR Vacuum Circuit Breaker Ratings ......................................................................................... 2
5.1 Typical Opening and Closing Times Value ................................................................................................ 32
6.1 Test Voltage. ............................................................................................................................................... 39
6.2 Typical Resistance Measurements ............................................................................................................. 42
7.1 Recommended W-VAC and W-VACW Spare Parts .................................................................................. 50