Section 2: System Specifications
Ozone Generator ZO-200-CD
Lamp: Corona Discharge
Operating Temperature: 35º F to 100º F
Ozone Output: 5.0 SCFH @ 2 PSI
Cabinet: Metal Construction
Check Valve : 1/4" Plastic Internal
Pressure Switch MCS4FORMCDN
Material: conforms to IEC 947, en 60-947, VDE
0660, csac2 2-2
Temperature: -10ºf min - to 150ºf max
Max Pressure: 65 PSI (4.4 bar)
Reading: Service Filter
Set Point: 10 PSI
Reading Pickup: Inlet Header of Hurricane Vessel
Service Beacon Dry contact
Bulb: 5w
Enclosure: IP54 /UL Type 12
Triggered by: TDS meter
Set Point: see TDS settings/ Descending Pressure Switch
Location: Dry Contact signal
Pressure Gauge WJF-GA-0-60
Range: 0-60 PSI
Face Diameter: 2 1/2"
Inlet Size: 1/4" NPT
Case Material: Stainless Steel
Wetted Parts: Brass
Settling Weir
Dimension: 36” l x 24” h x24” w
Inlet: 1.5” BHF connection
Outlet: 1.5” BHF connection
Material of Construction: Carbon Steel
Thickness: 10 gauge
Media Requirement (if equipped): WJF-SWB
Heat Exchanger 36,000 BTU
Capacity 36,000 BTU/HR
Inlet connection size: 1.0” NPT [x2]
Outlet connection size: 1.0” NPT [x2]