VEHICLE HEATERS – TECHNICAL DOCUMENTATION | 11
OPENING THE VEHICLE WORKSHOP MENU
Display On, the Start display appears.
Use the
or button to select the
symbol in the Menu bar.
10:30
Mo.
Confirm the SETTINGS menu item by pressing
the button.
Press the LONGPRESS button for longer
than 5 sec.; the Workshop menu is displayed.
SELECTING THE SETTINGS FOR THE STAND-
ARD CONFIGURATION
SELECTING THE TEMPERATURE UNITS – ITEM 2:
Default: °C
Use the
or button to select Item 2:
and confirm by pressing the button.
Use the
or button to select the tem-
perature units °C or °F.
Press the button to confirm the selection.
CHANGING THE PRESET OPERATING TIME –
ITEM 4.1:
Default: Water heater = 30 min. / Air heater =
continuous heating mode
Use the
or button to select Item 4.1:
and confirm by pressing the button.
The
or button can be used to set the
operating time.
Operating time setting range:
10 – 120 min. in 1 min. increments, continu-
ous heating mode is possible for air heaters.
From the 120th min. the operating time
can be extended in 5 min. increments up to
720 min.
Press the button to confirm the setting.
3 STARTUP / CONFIGURATION