EasyManua.ls Logo

Eberspächer EasyStart Timer - HEATING ON WITH SHORTPRESS AND WITH SETTINGS; SET TEMPERATURE SETPOINT - FOR AIR HEATERS ONLY

Eberspächer EasyStart Timer
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VEHICLE HEATERS – TECHNICAL DOCUMENTATION | 11
OPENING THE VEHICLE WORKSHOP MENU
Display On, the Start display appears.
Use the
or button to select the
symbol in the Menu bar.
10:30
Mo.
Confirm the SETTINGS menu item by pressing
the button.
Press the LONGPRESS button for longer
than 5 sec.; the Workshop menu is displayed.
SELECTING THE SETTINGS FOR THE STAND-
ARD CONFIGURATION
SELECTING THE TEMPERATURE UNITS – ITEM 2:
Default: °C
Use the
or button to select Item 2:
and confirm by pressing the button.
Use the
or button to select the tem-
perature units °C or °F.
2: 18 °C
SERVICE
2: 64.4 °F
SERVICE
Press the button to confirm the selection.
CHANGING THE PRESET OPERATING TIME –
ITEM 4.1:
Default: Water heater = 30 min. / Air heater =
continuous heating mode
Use the
or button to select Item 4.1:
and confirm by pressing the button.
The
or button can be used to set the
operating time.
Operating time setting range:
10 – 120 min. in 1 min. increments, continu-
ous heating mode is possible for air heaters.
From the 120th min. the operating time
can be extended in 5 min. increments up to
720 min.
4.1: 240