14 | VEHICLE HEATERS – TECHNICAL DOCUMENTATION
3 STARTUP / CONFIGURATION
FOR AUTOMATIC OPERATING TIME CALCULA-
TION, ENTER THE OPERATING TIME – ITEM
11.3:
Default: 60 minutes
Use the
or button to select Item
11.3: and confirm by pressing the button.
Use the
or button to set the operat-
ing time.
Setting range: 10 60 minutes.
11.3: 60
SERVICE
Press the button to confirm the setting.
PLEASE NOTE!
Press the
button to exit the Workshop
menu.
If the vehicle is only used for short trips,
consult the customer and reduce the maxi-
mum operating time.
Carry out a function test after configuration.