EasyManua.ls Logo

Eberspächer Easystart Remote + - User Manual

Eberspächer Easystart Remote +
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
OPERATING INSTRUCTIONS
QUICK START GUIDE
INSTALLATION INSTRUCTIONS
A WORLD OF COMFORT
DE
EN
INSTALLATION INSTRUCTIONS
EASYSTART REMOTE
+
VEHICLE HEATERS | TECHNICAL DOCUMENTATION
CONTROL UNIT FOR
EBERSPÄCHER PARKING HEATERS
Question and Answer IconNeed help?

Do you have a question about the Eberspächer Easystart Remote + and is the answer not in the manual?

Summary

INTRODUCTION

Please Read First

Important information before starting installation and operation.

General Information and Safety Instructions

Range, safety precautions, and essential operating guidelines for the unit.

Intended Use

Defines the proper application of the EasyStart Remote+ for vehicle heaters.

Ventilation Operating Mode

Explains the VENTILATION mode function for different heater types.

Technical Data

Lists operational specifications, dimensions, and temperature ranges for the units.

Scope of Supply

Details all components included in the EasyStart Remote+ package.

Sketch of EasyStart Remote+ Scope of Supply

Visual guide to all parts included in the EasyStart Remote+ kit.

INSTALLATION

Installation Overview

General guidance for installing the stationary unit, button, sensor, and antenna.

Key Installation Steps

Instructions for installing the stationary unit, button, and temperature sensor.

Connecting the Connector Housing

Procedure for connecting the wiring harness to the stationary unit.

Sketch of EasyStart Remote+ Installation

Diagram illustrating the physical installation of EasyStart Remote+ components.

Connecting the Antenna

Instructions for routing the antenna cable and connecting it to the stationary unit.

Minimum Height of the Antenna

Recommended minimum height for antenna placement to ensure optimal range.

Antenna Dimensions

Specifications and visual representation of the antenna's physical dimensions.

INITIAL STARTUP

Carry Out Initial Startup

Steps for battery insertion, voltage application, and mobile unit teaching.

Teach Additional Mobile Unit

Procedure for pairing additional remote control units with the stationary unit.

Configure EasyStart Remote+

Instructions for configuring the system based on its intended use.

Open Vehicle Workshop Menu

Steps to access and navigate the vehicle workshop menu for advanced settings.

Select Temperature Units

How to choose between Celsius (°C) and Fahrenheit (°F) for temperature display.

Reset to As-Delivered Condition

Procedure for resetting the system to its factory default settings.

Range Measurement

How to perform a range check measurement for the remote control's effectiveness.

Setting the Language

Instructions for selecting the display language between German (DE) and English (EN).

Select Departure Time or Start Time

Setting the departure time and start time functions for the heater's operation.

Activate;Deactivate Automatic Operating Time Calculation

Enabling or disabling automatic calculation of operating time for water heaters.

Enter Vehicle Engine Size for Auto Calculation

Inputting the engine's cubic capacity for automatic operating time calculation.

Enter Operating Time for Auto Calculation

Setting the desired operating duration for automatic heater operation.

WHAT TO DO IF...?

Troubleshooting Common Displays

Common error displays like 'Pair mode Add', 'NO SIGNAL', and heater faults with remedies.

Troubleshooting Mobile Unit Issues

Resolving issues like mobile unit not activating, battery problems, and LED indicator status.

CIRCUIT DIAGRAM

Connection Diagram for Hydronic Heaters

Wiring diagram for connecting EasyStart Remote+ to Hydronic, Hydronic II, and Hydronic M II heaters.

Connection Diagram for Airtronic Heaters

Wiring diagram for connecting EasyStart Remote+ to Airtronic heaters.

SERVICE

Technical Support Contact

Contact information for technical assistance with the heater or control unit.

Summary

INTRODUCTION

Please Read First

Important information before starting installation and operation.

General Information and Safety Instructions

Range, safety precautions, and essential operating guidelines for the unit.

Intended Use

Defines the proper application of the EasyStart Remote+ for vehicle heaters.

Ventilation Operating Mode

Explains the VENTILATION mode function for different heater types.

Technical Data

Lists operational specifications, dimensions, and temperature ranges for the units.

Scope of Supply

Details all components included in the EasyStart Remote+ package.

Sketch of EasyStart Remote+ Scope of Supply

Visual guide to all parts included in the EasyStart Remote+ kit.

INSTALLATION

Installation Overview

General guidance for installing the stationary unit, button, sensor, and antenna.

Key Installation Steps

Instructions for installing the stationary unit, button, and temperature sensor.

Connecting the Connector Housing

Procedure for connecting the wiring harness to the stationary unit.

Sketch of EasyStart Remote+ Installation

Diagram illustrating the physical installation of EasyStart Remote+ components.

Connecting the Antenna

Instructions for routing the antenna cable and connecting it to the stationary unit.

Minimum Height of the Antenna

Recommended minimum height for antenna placement to ensure optimal range.

Antenna Dimensions

Specifications and visual representation of the antenna's physical dimensions.

INITIAL STARTUP

Carry Out Initial Startup

Steps for battery insertion, voltage application, and mobile unit teaching.

Teach Additional Mobile Unit

Procedure for pairing additional remote control units with the stationary unit.

Configure EasyStart Remote+

Instructions for configuring the system based on its intended use.

Open Vehicle Workshop Menu

Steps to access and navigate the vehicle workshop menu for advanced settings.

Select Temperature Units

How to choose between Celsius (°C) and Fahrenheit (°F) for temperature display.

Reset to As-Delivered Condition

Procedure for resetting the system to its factory default settings.

Range Measurement

How to perform a range check measurement for the remote control's effectiveness.

Setting the Language

Instructions for selecting the display language between German (DE) and English (EN).

Select Departure Time or Start Time

Setting the departure time and start time functions for the heater's operation.

Activate;Deactivate Automatic Operating Time Calculation

Enabling or disabling automatic calculation of operating time for water heaters.

Enter Vehicle Engine Size for Auto Calculation

Inputting the engine's cubic capacity for automatic operating time calculation.

Enter Operating Time for Auto Calculation

Setting the desired operating duration for automatic heater operation.

WHAT TO DO IF...?

Troubleshooting Common Displays

Common error displays like 'Pair mode Add', 'NO SIGNAL', and heater faults with remedies.

Troubleshooting Mobile Unit Issues

Resolving issues like mobile unit not activating, battery problems, and LED indicator status.

CIRCUIT DIAGRAM

Connection Diagram for Hydronic Heaters

Wiring diagram for connecting EasyStart Remote+ to Hydronic, Hydronic II, and Hydronic M II heaters.

Connection Diagram for Airtronic Heaters

Wiring diagram for connecting EasyStart Remote+ to Airtronic heaters.

SERVICE

Technical Support Contact

Contact information for technical assistance with the heater or control unit.

Eberspächer Easystart Remote + Specifications

General IconGeneral
TypeRemote control
Operating Temperature-20°C to +60°C
DisplayLCD
RangeUp to 1000 meters (open area)
Featurestimer function
Battery LifeApproximately 1 year (depending on usage)