Operating instructions
8300100101
VBH0560CTTRS
Translation of the original operating instructions
ebm-papst Mulfingen GmbH & Co. KG
Bachmühle 2
D-74673 Mulfingen
Phone +49 (0) 7938 81-0
Fax +49 (0) 7938 81-110
info1@de.ebmpapst.com
www.ebmpapst.com
CONTENTS
1. SAFETY REGULATIONS AND INFORMATION
11. SAFETY REGULATIONS AND INFORMATION
Read these operating instructions carefully before starting work on the
device. Observe the following warnings to prevent malfunctions or
danger to persons.
These operating instructions are to be regarded as part of the device.
The device is only to be sold or passed on together with the operating
instructions.
These operating instructions may be duplicated and distributed to inform
about potential dangers and their prevention.
1.1 Hazard levels for warnings
11.1 Hazard levels for warnings
These operating instructions use the following hazard levels to indicate
potentially hazardous situations and important safety regulations:
DANGER
Indicates an imminently hazardous situation which will result in
death or serious injury if the specified actions are not taken.
Compliance with the instructions is imperative.
WARNING
Indicates a potentially hazardous situation which can result in
death or serious injury if the specified actions are not taken.
Exercise extreme caution while working.
CAUTION
Indicates a potentially hazardous situation which can result in
minor or moderate injury or damage to property if the specified
actions are not taken.
NOTE
A potentially harmful situation can occur and, if not avoided, can
lead to property damage.
1.2 Staff qualifications
11.2 Staff qualifications
The device may only be transported, unpacked, installed, operated,
maintained and otherwise used by suitably qualified, trained and
authorized technical staff.
Only authorized specialists are permitted to install the device, to carry
out a test run and to perform work on the electrical installation.
1.3 Basic safety rules
11.3 Basic safety rules
The safety hazards associated with the device must be assessed again
following installation in the final product.
The locally applicable industrial safety regulations are always to be
observed when working on the device.
Keep the workplace clean and tidy. Untidiness in the work area
increases the risk of accidents.
Note the following when working on the device:
; Do not perform any modifications, additions or conversions on the
device without the approval of ebm-papst.
WARNING
To reduce the risk of fire, electric shock or injury to people, do
not use any replacement or add-on parts that have not been
approved by ebm-papst (e.g. parts manufactured with a 3D
printer).
21.4 Voltage
21.5 Safety and protective features
21.6 Electromagnetic radiation
21.7 Mechanical movement
21.8 Emissions
21.9 Hot surface
21.10 Transport
31.11 Storage
32. INTENDED USE
43. TECHNICAL DATA
43.1 Product drawing
53.2 Nominal data
53.3 Data according to Commission Regulation (EU) 327/2011
53.4 Technical description
63.5 Mounting data
63.6 Transport and storage conditions
63.7 Electromagnetic compatibility
64. CONNECTION AND STARTUP
64.1 Mechanical connection
74.2 Electrical connection
84.3 Connection in terminal box
104.4 Connection diagram
114.5 Configuration options
124.6 Equivalent circuit diagrams
134.7 Checking connections
134.8 Switching on the device
134.9 Switching off the device
134.10 Suppression of speed ranges
135. INTEGRATED PROTECTIVE FEATURES
146. MAINTENANCE, MALFUNCTIONS, POSSIBLE
CAUSES AND REMEDIES
146.1 Warning/status codes
156.2 Vibration testing
156.3 Cleaning
166.4 Safety inspection
166.5 Disposal
Item no. 1170000596 · ENU · Change 262664 · Approved 2022-10-26 · Page 1 / 16
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Question and Answer IconNeed help?

Do you have a question about the ebm-papst VBH0560CTTRS and is the answer not in the manual?

Summary

1. SAFETY REGULATIONS AND INFORMATION

1.1 Hazard levels for warnings

Explains hazard levels (DANGER, WARNING, CAUTION, NOTE) used in the document.

1.2 Staff qualifications

Specifies the required qualifications for personnel working with the device.

1.3 Basic safety rules

Outlines fundamental safety principles to be observed during operation and maintenance.

1. SAFETY REGULATIONS AND INFORMATION

1.4 Voltage

Provides safety information and precautions related to the device's electrical voltage.

1.5 Safety and protective features

Details the safety features and protective measures integrated into the device.

1.7 Mechanical movement

Covers hazards associated with rotating parts and necessary precautions.

1. SAFETY REGULATIONS AND INFORMATION

1.11 Storage

Gives instructions and conditions for proper storage of the device.

2. INTENDED USE

Improper use

Lists prohibited and hazardous ways of operating the device.

3. TECHNICAL DATA

3.1 Product drawing

Displays a detailed technical drawing of the product with dimensions and component identification.

3. TECHNICAL DATA

3.2 Nominal data

Presents the key technical specifications and operational parameters of the device.

3.3 Data according to Commission Regulation (EU) 327;2011

Provides energy efficiency data as per the specified EU regulation.

3.4 Technical description

Offers a general technical overview and features of the device.

3. TECHNICAL DATA

3.5 Mounting data

Specifies requirements and data related to the mounting of the device.

4. CONNECTION AND STARTUP

4.1 Mechanical connection

Provides instructions and precautions for physically connecting the device.

4. CONNECTION AND STARTUP

4.2 Electrical connection

Covers the safety precautions and procedures for making electrical connections.

4.2.1 Requirements

Lists essential requirements before performing electrical connection.

4.2.2 Supply connection and fuses

Details the supply connection specifications and recommended fuses.

4. CONNECTION AND STARTUP

4.2.4 Residual current circuit breaker (RCCB)

Advises on the use and type of residual current devices.

4.3 Connection in terminal box

Guides on preparing and connecting cables within the terminal box.

4.3.1 Preparing cables for connection

Instructions on stripping cables and preparing them for connection.

4. CONNECTION AND STARTUP

4.3.3 Connect cables to terminals

Step-by-step guide on connecting cables to the device terminals.

4.3.4 Cable routing

Instructions on how to route cables to prevent moisture penetration.

4. CONNECTION AND STARTUP

4.4 Connection diagram

Illustrates the electrical connection diagram of the device.

4. CONNECTION AND STARTUP

4.5 Configuration options

Details various configurable options for the device's inputs and outputs.

4.6 Equivalent circuit diagrams

4. CONNECTION AND STARTUP

4.8 Switching on the device

Provides instructions and warnings for safely switching on the device after installation.

5. INTEGRATED PROTECTIVE FEATURES

Integrated protective features

Describes the device's protective functions and their behavior during faults.

6. MAINTENANCE, MALFUNCTIONS, POSSIBLE CAUSES AND REMEDIES

6.1 Warning;status codes

Explains the LED indicators and their associated warning/status codes.

6.2 Vibration testing

Details procedures for performing manual vibration tests on the fan.

6. MAINTENANCE, MALFUNCTIONS, POSSIBLE CAUSES AND REMEDIES

6.1.2 Status codes

Lists status codes related to faults, their causes, and remedies.

6.3 Cleaning

Provides instructions and precautions for cleaning the device.

6.4 Safety inspection

Outlines the schedule and procedures for safety inspections.

6. MAINTENANCE, MALFUNCTIONS, POSSIBLE CAUSES AND REMEDIES

6.4 Safety inspection

Details checks for contact protection, blades, housing, cables, and glands.

6.5 Disposal

Provides recommendations for the ecological disposal of the product and its components.

6.5.1 Country-specific legal requirements

Highlights legal requirements for product disposal in different countries.

6.5.2 Disassembly

Gives instructions for safe disassembly of the product by qualified personnel.

6.5.3 Component disposal

Lists categories for separating components for recycling.

ebm-papst VBH0560CTTRS Specifications

General IconGeneral
Manufacturerebm-papst
ModelVBH0560CTTRS
CategoryFan
Voltage24 VDC
Dimensions60 x 60 x 25 mm
Bearing TypeBall Bearing
Speed3000 rpm
ConnectorTerminals