WX2NB Manual v.1.0 Page 37 / 40
8. RECEIVING OF MESSAGE
OSM.Server supports sending remote commands in a form designed specially for
WX2NB. If a message received by the device is incorrect, it is deleted automatically
and the device takes no action.
8.1. LX PROTOCOL
The following message format is accepted:
SERVICE CODE█COMMAND█COMMAND█..........
Where:
SERVICE CODE - device service code
█ - SPACE
COMMAND - order (see the table below)
List of commands
Disconnects active TCP connection.
Reset modem; after execution of command a
confirmation is sent.
Resets device. Note: all unsent events will be lost.
Turn on or turn off outputs. outNr specifies output
number (0 for OUT1), state specifies requested
output state (0 – switched off, 1 – switched on).
Below are allowed combinations:
OUT=0,0 – switches off TMP output
OUT=0,1 – switches on TMP output
Returns device description, serial number
(hexadecimal number) and firmware version.
Gets primary communication parameters of device
Server address; it can be in form of IP or domain
name address.
Removes automatic temporary locks on all inputs
Removes selected automatic temporary locks.
Parameter is decimal number made from 9-bit word:
A2, A1, where A2 means INPUT 1, A3 INPUT 2, A4
INPUT 3, A5 INPUT 4.
EXAMPLE:
RLIMIT=6 removes locks on inputs: IN1, IN2
RLIMIT=2 remove lock on input IN1
Flushes events buffer, where x is:
2 – system events history