Chengdu Ebyte Electronic Technology Co., Ltd E104-BT11 User Manual
Copyright ©2012–2020Chengdu Ebyte Electronic Technology Co., Ltd
18
5.4.1.12 Baud rate read
Operation code
Parameter
Request
0x0F
N/A
Response
0x0F
Returns the serial number of the set baud rate (see definition in baud rate setting)
For example,
Request
02 C0 0F
Response
03 40 0F 0C
Remark
5.4.1.13 MAC read
Operation code
Parameter
Request
0x11
N/A
Response
0x11
Returns current MAC address
For
example,
Request
02 C0 11
Response
08 40 11 11 22 33 44 55 66
Remark
5.4.1.14 Power configuration
Operation code
Parameter (1 byte)
Request
0x12
Power parameter
Response
0x12
Power parameter
For example,
Request
03 C0 12 11
Response
03 40 12 10
Remark
1. The step value of the power parameter is 0.2. For example, 10 is 1.0dbm, 55 is 5.5dbm;
2. The module response is different from the request parameter, and the actual return shall prevail.
3. During power setting, ble may be disconnected, which is normal.
4. Effective immediately, save after power off.
5.4.1.15 Power read
Operation code
Parameter
Request
0x13
N/A
Response
0x13
Returns current power
For example,
Request
02 C0 13
Response
03 40 13 10
Remark
The step value of the power parameter is 0.2. For example, 10 is 1.0dbm, 55 is 5.5dbm;