Chengdu Ebyte Electronic Technology Co., Ltd E32-900T20D User Manual
Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd. 16
Low address byte of module
(the default 00H)
UART mode can be different between
communication parties
UART baud rate can be different between
communication parties
The UART baud rate has nothing to do
with wireless transmission parameters &
won’t affect the wireless transmit / receive
features.
The lower the air data rate, the longer the
transmitting distance, better
anti-interference performance and longer
transmitting time
The air data rate must keep the same for
both communication parties.
00H-45H, correspond to 862~931MHz
4-0, channel (862M + CHAN*1M), default 06H(868MHz)
Fixed transmission enabling bit(similar to MODBUS)
In fixed transmission mode, the first three
bytes of each user's data frame can be used
as high/low address and channel. The
module changes its address and channel
when transmit. And it will revert to
original setting after complete the process.
Transparent transmission mode
IO drive mode (default 1)
This bit is used to the module internal
pull-up resistor. It also increases the
level’s adaptability in case of open drain.
But in some cases, it may need external
pull-up resistor.
TXD and AUX push-pull outputs, RXD pull-up inputs
TXD、AUX open-collector outputs, RXD open-collector
inputs