Chengdu Ebyte Electronic Technology Co.,Ltd.. E52-400/900NW22S User Manual
CopyriCopyright ©2012–2023, Chengdu Ebyte Electronic Technology Co.,Ltd.
Some function indication pins, high level by default, active low level
(connected to test suite LED2)
RF transmission indication pin, default high level, active low level
(connected to test suite LED1)
Not used yet, NC recommended
Not used yet, NC recommended
Not used yet, NC recommended
Not used yet, NC recommended
Default is high level, pull it low when power on to enter the Bootloader
(connected to the test suite KEY button)
Not used yet, NC recommended
UART_TXD, serial port transmit pin
UART_RXD, serial port receiving pin
Not used yet, NC recommended
Not used yet, NC recommended
Ground wire, connected to the power reference ground
Antenna interface, 50Ω characteristic impedance (connected to SMA
interface of test kit)
Ground wire, connected to the power reference ground
Not used yet, NC recommended
Reset pin, default high level, active low level (connected to test suite RST
button)
Not used yet, NC recommended
Not used yet, NC recommended
Not used yet, NC recommended
Not used yet, NC recommended
Not used yet, NC recommended
Not used yet, NC recommended
Not used yet, NC recommended
Not used yet, NC recommended
Not used yet, NC recommended
Ground wire, connected to the power reference ground
Power supply VDD, the maximum input voltage is 3.6V, it is recommended
to supply power through 3.3V LDO