6.6 Parameter Notes
If the setting command does not have the save option <save> parameter, it will be saved in Flash.
After the baud rate <baud> and parity bit <parity> are set, a reboot is required to take effect. You can use
"AT+RESET" to reset.
Address <addr> and network identification code <panid> are generally not recommended to be set to 0xFFFF.
0xFFFF is used as a broadcast address and broadcast network.
Node type <type> will change the highest bit of the local address. Generally, you need to set the node type <type>
after setting the local address <addr>.
Set the node type of the module
Set the node type of the module
[0: Routing node 1: Terminal node]
Address range [0x0000~0xFFFE]
Routing node: 0x0000~0x7FFF
Terminal node: 0x8000~0xFFFE
Set multicast group address
Group address range [0x0000~0xFFFE]
Different ports correspond to different
functions, and the remaining ports have no
functions yet.
Port 1: Output data directly through UART
Port 14: Parse data as AT commands
Set the propagation radius under
multicast
Multicast propagation radius[0~15]
The larger the radius, the greater the number
of propagation stages.
Set CSMA random avoidance
time
Random avoidance time [20~65535] ms
Set the maximum number of
consecutive failures,Exceeding
this will require re-initiating the
routing request
Maximum number of consecutive failures
[1~15]
Various function switches
[1: Function enabled 0: Function disabled]
Automatic reset time [1~255] min
[0: Turn off automatic reset]
Broadcast filter timeout [3000~65535] ms
Request response timeout [1000~65535] ms
Routing request timeout [1000~65535] ms
Encryption key [0~0x7FFF FFFF]