EasyManua.ls Logo

Ebyte E77-M22S Series - Page 24

Ebyte E77-M22S Series
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chengdu Ebyte Electronic Technology Co., Ltd. E77-xxxM22S User Manual
Copyright © 2012-2 024 , Chengdu Ebyte Electronic Technology Co., Ltd.
22
command
character
Command
type
Command format
response
DUTYCYCLE
( Set duty
cycle )
test
command
AT+DUTYCYCLE?
AT+DUTYCYCLE=<DutyCycle><CR>. Get or
Set the ETSI DutyCycle=[0:disable, 1:enable] -
Only for testing
Query
command
AT+DUTYCYCLE = ?
<DutyCycle>
OK
Set
command
AT+DUTYCYCLE ==
<DutyCycle>
OK
Parameter
Description
<DutyCycle>
0: Turn off ETSI duty cycle
1: Turn on ETSI duty cycle
Return
value
description
Example
AT+DUTYCYCLE =0
OK
Precautions
After DCS is turned on, the data sending frequency complies with the lorawan
protocol standard, and the duty cycle is generally 1%. After sending one packet
of data at low airspeed, it will take a long time to send the next packet.
command
character
Command
type
Command format
response
CTXP
(Set transmit
power)
test
command
AT+CTXP?
+CTXP: " value "
OK
Query
command
AT+CTXP = ?
+CTXP:<value>
OK
Set
command
AT+CTXP=<value>
OK
Parameter
Description
<value>: It is the sending power. The factory value is 0. Different regional
standards have different maximum powers.
0-17dBm
1-15dBm
2-13dBm
3-11dBm
4-9dBm
5-7dBm
6-5dBm
7-3dBm
Return
value
description
Example
AT+CTXP=1
OK
Notice
The power here is the standard of cn470, which varies in different regions. See
Appendix 2.