Chengdu Ebyte Electronic Technology Co., Ltd. E77-xxxM22S User Manual
Copyright © 2012-2 024 , Chengdu Ebyte Electronic Technology Co., Ltd.
29
character
type
CJN2DL
(Set the
network access
rx2 window
delay)
test
command
AT+CJN2DL?
AT+CJN 2 DL=<Delay><CR>. Get or Set the
Join Accept Delay between the end of the Tx and
the Join Rx Window 2 in ms
Query
command
AT+CJN2DL?
<Delay>
OK
Set
command
AT+CJN 2 DL=<Delay>
OK
Parameter
Description
<Delay> Gets or sets the Join-Accept Delay (milliseconds) between the end of
Tx and Join-Rx window 2
Return
value
description
Example
AT+CJN 2 DL= 2000
Notice
Rx2_delay=rx1_delay+1000 ms
command
character
Command
type
Command format
response
CRX1DL (set
rx1 window
delay)
test
command
AT+ CRX1DL ?
AT+CRX1DL=<Delay><CR>. Get or Set the
delay between the end of the Tx and the Rx
Window 1 in ms
Query
command
AT+ CRX1DL ?
<Delay>
OK
Set
command
AT+ CRX1DL =<Delay>
OK
Parameter
Description
<Delay> Gets or sets the delay between the end of Tx and Rx window 1, in ms
Return
value
description
Example
AT+CJN 2 DL= 2000
Notice
There is no need to set it up. If it is set up on the server, the module will
automatically synchronize.
command
character
Command
type
Command format
response
CRX2DL (set
rx2 window
delay)
test
command
AT+ CRX2DL ?
AT+CRX1DL=<Delay><CR>. Get or Set the
delay between the end of the Tx and the Rx
Window 2 in ms
Query
command
AT+ CRX2DL ?
<Delay>
OK
Set
command
AT+ CRX2DL =<Delay>
OK