25
CWORKMODE
( Set working
mode )
test
command
AT+CWORKMODE=?
+CWORKMODE: " mode "
OK
query
command
AT+CWORKMODE?
+CWORKMODE:<mode>
OK
set
command
AT+CWORKMODE=<mode>
OK
Parameter
Description
<mode>:
2: Normal working mode
Return
value
description
example
AT+CWORKMODE=2
OK
Precautions
It needs to be set before Join, and the default is normal working mode. Currently
only supports normal working mode
command
character
command
type
command format
response
CCLASS
( set Class )
test
command
AT+CCLASS=?
+CCLASS: " class " , " branch " , " para1 " ,
" para2 " ,
" para3 " , " para4 "
OK
query
command
AT+CCLASS?
+CCLASS:<class>
OK
set
command
AT+CCLASS=<class>
OK
Parameter
Description
<class>:
0:classA
2: classC
Return
value
description
example
AT+CCLASS=2
OK
Precautions
It needs to be set before Join, the default is classA
command
character
command
type
command format
response
CSTAUS
( query the
current status
of the device )
test
command
AT+CSTAUS=?
+CSTATUS: " status "
OK
query
command
AT+CSTATUS?
+CSTATUS:<status>
OK
Parameter
Description
<status>:
00 no data operation
01 Data sending
Return value