Copyright©2012–2023, Chengdu Ebyte Electronic Technology Co., Ltd.
32
CNBTRIALS
( Set the
number of
times to send )
+CNBTRIALS: " MType " , " value "
OK
+CNBTRIALS:<MType>,<value>
OK
AT+CNBTRIALS=<MType>,<va
lue>
<MType>: 0: unconfirm package, 1: confirm package.
<value>: It is the maximum sending times, value range: 1~15;
Need to set before sending data
+CRM: " reportMode " , " reportInterval "
OK
+CTXP:<reportMode>,[reportInterval]
OK
AT+CTXP=<reportMode>,[report
Interval]
<reportMode>:
0- report data
aperiodically; 1- report data periodically;
<reportInterval>: This parameter is only available when reporting data periodically.
The time interval for reporting data periodically, unit: s.
For different DRs, the allowed minimum cycle is different, defined by the cycle
level, as shown in the table below.
Rate\Period(s)\Level LV1 LV2
DR0 150 300
DR1 75 150
DR2 35 70
DR3 15 30
DR4 10 20
DR5 5 10