EasyManuals Logo

Ebyte E840-DTU User Manual

Ebyte E840-DTU
33 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
Chengdu Ebyte Electronic Technology Co.,Ltd E840-DTU(4G-02E) User Manual
Copyright ©2012–2019
Chengdu Ebyte Electronic Technology Co.,Ltd
24
AT+LINKSTA2
Function inquire whether TCP connection is established
Format
inquire
transmitAT+LINKSTA2<CR>
return<CR><LF>+OK=<sta><CR><LF>
Parameter
Sta whether establish TCP connection
Connect(TCP connection)/ Disconnect(TCP cut off)
AT+LINKSTA3
Function inquire whether TCP connection is established
Format inquire
transmit
AT+LINKSTA3<CR>
return<CR><LF>+OK=<sta><CR><LF>
Parameter Sta whether establish TCP connectionConnect(TCP connection)/ Disconnect(TCP cut off)
AT+SOCK
Function
Set/query the network protocol parameter format.
Format inquire
transmitAT+SOCK<CR>
return
<CR><LF>+OK=<protocol>,<ip>,< port ><CR><LF>
configure
transmit
AT+SOCK=<protocol>,<ip>,< port ><CR>
return<CR><LF>+OK<CR><LF>
Parameter
protocol protocol type
TCPC / UDPC
TCPC corresponding TCP client
UDPC corresponding UDP client
Ip The IP address or domain name of the target server when the module is set to "CLIENT"
Port The port number of the server, in decimal, less than 65535.
AT+SOCK1
Function
Set/query the network protocol parameter format.
Format inquire
transmitAT+SOCK1<CR>
return<CR><LF>+OK=<EN>,<protocol>,<ip>,< port ><CR><LF>
configure
transmitAT+SOCK1=<EN>,<protocol>,<ip>,< port ><CR>
return
<CR><LF>+OK<CR><LF>
Parameter
EN enable 0
turn off SOCK1
1turn on SOCK1
protocol type TCPC / UDPC
TCPC corresponding TCP client
UDPC corresponding UDP client
Ip The IP address or domain name of the target server when the module is set to "CLIENT"
Port The port number of the server, in decimal, less than 65535.
AT+SOCK2
Function
Set/query the network protocol parameter format.
Format inquire
transmitAT+SOCK2<CR>
return
<CR><LF>+OK=<EN>,<protocol>,<ip>,< port ><CR><LF>
configure
transmiAT+SOCK2=<EN>,<protocol>,<ip>,< port ><CR>
return
<CR><LF>+OK<CR><LF>
Parameter EN enable 0turn off SOCK2
1turn on SOCK2
protocol type
TCPC / UDPC
TCPC corresponding TCP client
UDPC corresponding UDP client
Ip The IP address or domain name of the target server when the module is set to "CLIENT"
Port The port number of the server, in decimal, less than 65535.
AT+SOCK3