Installing the water heater, Continued....
US Installations1 Canadian Installations2
A = Clearance above grade,
veranda, porch, deck, or
balcony
12 in (30 cm) 12 in (30 cm)
B = Clearance to window or
door that may be opened
4 ft (1.2 m) below or to side
of opening; 1 ft (300 mm)
above opening
6 in (15 cm) for appliances ≤
10,000 Btuh (3 kW), 12 in (30
cm) for appliances > 10,000
Btuh (3 kW) and ≤ 100,000
Btuh (30 kW), 36 in
(91 cm) for appliance >
100,000 Btuh (30 kW)
C = Clearance to permanently
closed window
*
D = Vertical clearance to
ventilated soft located
above the terminal within
a horizontal distance of
2 feet (61 cm) from the
center line of the terminal
*
E = Clearance to unventilated
soft
*