39
Airow mode
• Press the mode button 5 on the control panel or the proper button 5 on the remote control to select
airow mode. The airow indicator is on.
• Press the air speed button 3 to choose between low, medium and high air speed.
Dehumidication mode
• Press the mode button 5 on the control panel or the proper button 5 on
the remote control to select dehumidication mode. The dehumidication
indicator is on.
• As indicated in the picture, pull the plug from the drain for draining the
condensate 9 and insert hose in the outlet. Put the other end of the hose in
asuitable container or asink.
• If in the dehumidication mode the temperature in the room is higher
than 15 °C, the air conditioning compressor starts working. The operation is
then controlled as follows: When the temperature in the room drops below
13 °C, the compressor stops. When the temperature rises again above 15⁰C,
the compressor starts again. If the interval between turning on and o the
compressor were less than 3 minutes, in order to protect the compressor
athree minutes delay was included before the restart.
• The fan runs by default at low speed and the speed of the airow cannot be set in the dehumidication
mode.
• Temperature cannot be set.
Tip: When using the dehumidifying function remove the exhaust hose from the air conditioner. Otherwise, the
dehumidication is not ecient or the alarm “FL” appears indicating that it is full of water.
Automatic mode
• Press mode button 5 on the control panel or the proper button 5 on the remote control to select
automatic mode. The automatic mode indicator lights up.
• After selecting automatic mode the operating status depends on the ambient temperature: When
the ambient temperature is above 25° C, the air conditioner runs in cooling mode. When the ambient
temperature is lower than 25 ° C, the air conditioning runs in airow mode.
Timer mode
• In the standby mode you can press the timer button 6 to set using the arrows 4 time to start the air
conditioning (1~24h). The timer indicator will light up.
• When turned on you can press the timer button 6 to set using arrows 4 time to shut o the air
conditioning (1~24h). The timer indicator will light up.
CARE AND MAINTENANCE
Emptying the water container
The appliance has an automatic water evaporation system. The circulation of condensed
water cools the evaporator. This not only increases the eciency of cooling, but also saves
energy.
When the water container is full the display shows message “FL” accompanied by acoustic
alarm. The compressor stops working automatically. In this case it is necessary to empty
the water. Proceed as follows:
1. Disconnect the appliance from power and remove the exhaust hose assembly.
2. Place the air conditioner in asuitable place.
3. Remove the drain plug and drain the water from the appliance.
4. Carefully replace the drain plug.
5. Put back the exhaust hose and switch on the air conditioner.