CARE AND MAINTENANCE
Emptying the water tank
The appliance has an automatic water evaporation system. The circulation of
condensed water cools the evaporator. This not only increases the eciency of
cooling, but also saves energy.
When the water container is full the display shows message “FL accompanied
by acoustic alarm. The compressor stops working automatically. In this case it is
necessary to empty the water. Proceed as follows:
1. Disconnect the appliance from power and remove the exhaust hose
assembly.
2. Place the air conditioner in asuitable place.
3. Remove the drain plug and drain the water from the appliance. You can lean
back the appliance slightly when draining it.
4. Carefully replace the drain plug.
5. Put back the exhaust hose and switch on the air conditioner.
Maintenance
Attention: Turn o the appliance and disconnect it from power before cleaning and maintenance to prevent
injury by electric shock!
Cleaning the external surface
1. Unplug the power supply from the outlet.
2. Wipe it with ane cloth. Do not use benzine, solvent or other chemicals for cleaning. These substances
could damage the surface of the device and deform plastic components.
3. Protect the appliance from water getting in.
Cleaning the lter
When the lter is gradually clogged with dust, the eciency of air conditioning
is reduced. If the lter becomes clogged and the air conditioning eciency
decreases, it is necessary to clean the lter. We recommend to clean the lter
every 14 days. If the air is polluted it is necessary to clean it more often.
Cleaning the top lter:
1. Grasp the outer grill of the EVA lter B, press the lock and remove the
grill. Then unscrew the four screws holding the lter in the appliance A.
2. Put the EVA lter in a solution of neutral detergent and warm water
(about 40°C) and after washing it let it dry in the shade.
3. Replace the clean lter back. Turn on the air conditioner and operate it
as usual.
Cleaning the bottom lter:
1. Grasp the grill of the CON lter and remove it carefully C.
2. Put the CON lter in asolution of neutral detergent and warm water (about 40°C) and after washing it let
it dry in the shade.
Notes:
To clean the lter do not use overly hot water (ideal temperature is about 40°C) and aggressive cleaning
agents (alcohol, gasoline, paint thinners).
To avoid deformation of the lter protect it from heat and let it dry by itself.
Do not operate the appliance without inserted lter.
Seasonal maintenance
If you are not using the appliance for longer time do the following seasonal maintenance:
1. Remove the drain plug and drain the water from the appliance.
2. Let the unit run two hours in air ow mode (low speed) until the inside dries out completely.