USING THE APPLIANCE
Note: The operating status in cooling mode depends on the ambient temperature: When the ambient
temperature reaches the value selected on the unit, the cooling function is switched o and only the
fan continues to operate. If the ambient temperature rises above the set value, the cooling function
switches on again.
Cooling and air ow mode
By default, the air conditioner is in cooling mode when switched on. You can also change the air conditioner
in the cooling mode using modes button 5. The cooling indicator is on.
Using the 4 buttons(up and down arrows) set the required temperature in the range 16 °C to 30 °C.
Press the air speed button 3 to select between low, medium and high air ow speed.
Airow mode
Press the mode button 5 on the control panel or the proper button 5 on the remote control to select
airow mode. The airow indicator is on.
Press the air speed button 3 to select between low, medium and high air ow speed.
Dehumidication mode
Press the mode button 5 on the control panel or the proper button 5 on
the remote control to select dehumidication mode. The dehumidication
indicator is on.
As shown in the picture, remove the plug from the condensation drain 9
and insert hose into the outlet. Put the other end of the hose in asuitable
container or asink.
In dehumidication mode, if the room temperature is above 17 ° C, the
air conditioning compressor will start operating. The operation is then
controlled as follows: When the temperature in the room drops below 15 °C,
the compressor stops. When the temperature rises again above 15⁰C, the
compressor starts again. If the compressors turn o and on time interval
is less than 3 minutes, a three-minute delay is included to protect the
compressor from restarting.
In dehumidication mode, the fan runs implicitly at low speed and the air ow rate cannot be adjusted.
Temperature cannot be set.
Tip: When using the dehumidifying function remove the exhaust hose from the air conditioner. Otherwise,
the dehumidication is not eective or the “FL alarm is displayed to indicate that the water tank has been
lled.
Timer mode
In the standby mode you can press the timer button 6 to set using the arrows 4 time to start the air
conditioning (1~24h). The timer indicator will light up.
When turned on you can press the timer button 6 to set using arrows 4 time to shut o the air
conditioning (1~24h). The timer indicator will light up.