TECHNICAL DATA
Manufacturer ECG
Model MK 94
Cooling yes
Dehumidication yes
Fan yes
Setting the fan speed 2 speed
On/O timer 1–24 hrs.
Thermostat 16–30 °C
Remote control yes (2× AAA batteries included)
Recommended room size 12–15m
2
Air ow 290 m³/h
Energy class A
Nominal input power 785 W
Nominal voltage 220–240 V~ 50 Hz
Noise level 65 dB (A)
Cooling performance 7000 Btu/h
Refrigerant R290/150 g
Output pressure 2,8 MPa
Suction pressure 0,8 MPa
Max. permissible pressure (low) 1,3 MPa
Max. permissible pressure (high) 3,8 MPa
Product weight 21 kg
Product weight including packaging 25 kg
Product dimensions (h × w× d) 690 × 370 × 350 mm
Dimensions including packaging (h × w× d) 830 × 445 × 375 mm
WARRANTY: The following situations void the warranty:
Incorrect or inappropriate handling of the device, failure to observe the safety precautions that apply to the
appliance, use of force, alteration or repair by aparty other than an authorized service center.
Components subject to normal wear and tear are not covered under the warranty.