Move the TRIM (3) control until the VU-meter shows 0dB.
7. Send the signal to the HOUSE
Rotate the channel 1 potentiometer (10) clockwise at its maximum.
8. Monitor the output with your headphones
Adjust the VOLUME controller (17) to obtain a comfortable monitoring volume.
Now you should hear music with your headphones. Turn the SOURCE
controller (18) clockwise to crossfade from the PFL signal to the MIX signal.
When this controller is completely turned to the right, only the MIX signal will
be monitored. In this case the PFL and the MIX signal are both referred to
channel 1 so you will listen the same signal in both positions.
9. Check the EQ operation
Adjust the EQ of the track with the 3-way stereo equaliser (4, 5, 6) and unleash
your creativity with the powerful 3-way isolator (12). This 4
th
order tone control
has been designed for a creative sound edition: each way can be individually
isolated and boosted using the big and ergonomic rotary controllers.