48 EC-11User’s Manual
03-32-00418-05 DALSA Corp.
D4 Networking Mode
• Not available at time of shipment. To be included in a later release.
D5 Examples
Example: To set the gain to –3.5
Short Form
set_gain –3.5 CR
Long Form
sg –3.5 CR
Example: To return the camera model number
Short Form
get_camera_model CR
Long Form
gcm CR
Example: to begin a camera calibration (dark
correction)
Short Form
correction_calibrate_fpn CR
or
correction_calibrate_fpn value CR
Long Form
ccf CR
or
ccf value CR
D6 Error Handling
• The camera will send ">" to an empty message (i.e. just a CR).
• All non-query functions return "OK >" unless an error occurs.
• If an error occurs, the function returns "Error x: Description >" where x is an error code
• Error codes include:
Cod
e
Description
0 OK
1 Internal camera error. Please report this error code to DALSA Corp.
2 Camera configuration error. Verify camera settings.
3 Invalid command.
4 Command parameters: invalid.
5 Command parameters: incorrect or out of range
6 General timeout error.
7 Unable to program internal FPGAs. Please report this error code to DALSA Inc.