Do you have a question about the Eco-Flo CDSP-20 and is the answer not in the manual?
Read and follow all safety instructions provided in this manual and on the pump. Save these instructions for future reference.
Explains safety alert symbols (DANGER, WARNING, CAUTION, NOTICE) and their meanings to ensure user safety.
Covers safe operation, preventing freezing, regular inspection, and wearing safety glasses during servicing.
A warning indicating the risk of pump body explosion if used as a booster pump.
Examine the pump and all parts for damage before use. Contact customer service if any part is damaged.
The pump is designed for condensate removal from AC evaporative coils, controlled by a float/switch mechanism.
Cycle AC several times to collect condensate, flushing residual oils before installing the pump.
Lists essential materials needed for installation, such as safety glasses, screwdriver, level, and fasteners.
Mount the unit level using slots on the tank ends, near the AC unit or wall, ensuring proper drain flow.
Turn off electrical power before wiring. Connect the power cord to a constant source following local codes.
Run inlet piping sloped downward for gravity flow and outlet piping for a siphoning effect to improve efficiency.
Test motor and safety switches by raising their floats before the cover contacts to ensure proper operation.
Manufacturer warrants products free from defects in material and workmanship for twelve months from the original purchase date.
Details warranty exclusions, limitations of remedies, and specifies purchaser's legal rights and manufacturer's obligations.
| Model | CDSP-20 |
|---|---|
| Maximum Flow Rate | 20 GPM |
| Maximum Head | 20 ft |
| Voltage | 115V |
| Flow Rate | 20 GPM |
| Max Head | 20 ft |