What to do if the EcoKing C100 Boiler water pressure is too low?
- JJustin McmillanAug 14, 2025
If the water pressure in your EcoKing Boiler is too low, re-fill the installation.
What to do if the EcoKing C100 Boiler water pressure is too low?
If the water pressure in your EcoKing Boiler is too low, re-fill the installation.
What to do if EcoKing C100 Boiler shows lock-out no ignition?
If your EcoKing Boiler is in lock-out with no ignition, check the CH connections.
What to do if EcoKing C100 Boiler shows lock-out Primary temperature too high (>95 ºC)?
If your EcoKing Boiler is in lock-out because the primary temperature is too high (over 95 ºC), check parameter 2.
What to do if EcoKing Boiler shows lock-out ionization problem - parasitic flame?
If your EcoKing Boiler is in lock-out due to an ionization problem with a parasitic flame, check parameter 0.
What to do if EcoKing C100 Boiler shows lock-out high limit temperature protection?
If your EcoKing Boiler is in lock-out due to high limit temperature protection, check parameter 1.
What to do if EcoKing Boiler shows lock-out Flame lost for 6 times?
If your EcoKing Boiler is in lock-out because the flame was lost 6 times, check the speed in the diagnose menu (24) and check parameters 4 and 5.
What to do if EcoKing C100 Boiler shows DHW sensor fault?
If there is a DHW sensor fault in your EcoKing Boiler, check the DHW temperature via the diagnose menu (8) and replace the sensor when required.
What to do if EcoKing Boiler shows flue gas blockage?
If your EcoKing Boiler has a flue gas blockage, check the flue pipe for blockages.
Critical safety instructions and warnings before appliance use.
Step-by-step guide for initial appliance startup and operation.
Procedure to safely shut off the gas supply to the appliance.
Details hazards and handling of components containing Crystalline Silica.
Critical warnings regarding water damage and proper site selection.
Crucial warnings about common venting and air intake contamination.
Guidelines for examining components and ensuring proper joint assembly.
Guidelines for installing vent systems through walls, including permits and checks.
Guidelines for installing vent systems through roofs, including permits and checks.
Essential steps before initial system startup for plastic venting.
Critical warnings regarding safe distances for vent and air inlet terminations.
Steps for safely removing an old boiler from a shared venting system.
Installation requirements for specific pipe materials in Canada.
Guidelines for sizing, connecting, and testing gas piping.
Critical warnings regarding gas leaks, open flames, and pressure testing.
Warnings about improper electrical connections and their consequences.
Warnings related to manual air bleed, venting, and general installation checks.
Essential safety checks and procedures before initiating operation.
Comprehensive steps for starting the boiler and ensuring proper function.
Procedure for safely turning off the gas supply to the appliance.
Instructions for filling the central heating system and monitoring pressure.
Step-by-step guide to accessing and adjusting boiler parameters.
How to adjust the maximum temperature setting for central heating.
Options for setting hot water comfort levels: Eco, Comfort, Ecomfort.
Step-by-step guide for manual calibration using a flue gas analyzer.
Critical warnings regarding the completion of the calibration process.
Procedure for automatic boiler calibration without external analysis.
Verification steps after installing piping, drains, and electrical connections.
Final checks for gas leaks, water pressure, and smooth operation.
Tasks to perform before leaving the installation site, including documentation.
Comprehensive checklist for yearly maintenance and inspection of the appliance.
Warnings and information regarding potential hazards of Crystalline Silica.
Safety measures to follow when servicing the appliance.
Checklist for verifying piping, pressurization, gas, condensate, calibration, and settings.
Table outlining routine inspection tasks for safe and efficient operation.