© 2015 Ecolink Intelligent Technology Inc. PN PIR-ZWAVE2 R1.04
To restore this sensor to factory default settings, follow the instructions in this manual to exclude this sensor from the Z-Wave network. Upon completion of
removal from the network the sensor will restore itself to factory default settings automatically. Use this procedure only in the event that the network primary
controller is missing or otherwise inoperable.
Keeping Awake for Testing and Configuration
To save power, this sensor sleeps most of the time and is therefore not awake to receive messages from a gateway for testing. Removing the top case from the
sensor will put in device into a tampered mode in which the sensor will stay awake and able to receive messages. Most of the time an end user would not do
this, but if the sensor needs to be configured after inclusion, an end user can follow the instructions below for sending Wake-Up notifications.
Association
This sensor has two Association groups of 5 nodes each. Group one is a lifeline group who will receive unsolicited messages relating to motion detection
notifications, case tampering notifications, low-battery notifications, and sensor binary reports. Group 2 is intended for devices that are to be controlled i.e.
turned on or off (on only by default) with a Basic Set. On inclusion the controller should put its node ID in group 1 but not group 2.
Network Wide Inclusion
This sensor also supports Network Wide Inclusion such that the Sensor can be included into the Z-Wave network over the mesh network and not directly near
the main controller. This mode is automatically activated after regular inclusion was not successful.
SENSOR CONDITION
COMMAND CLASS and VALUE
ASSOCIATION GROUP
CONFIGURABLE?
Motion Detected
Notification Report of
Home Security
(0x0
7
),
Motion Detection
Unknown Location(0x08)
1
Yes via Notification Set of notificationType
(0x07) and status of 0x00: This type of
notification turned off
0xFF: This type of notification turned on
Sensor Binary Report of 0xFF
Sensor Type: 0xFF
1
Yes via Configuration Command Class
Parameter Number: 2
Size: 1
A Configuration Value: 0xFF (On) / 0x00 (Off)
Basic set of 0xFF (On)
2
No
Notification Report of
Home Security
(0x0
7
),
Event
inactive(0x00)
1
Yes via Notification Set of notificationType
(0x07) and status of 0x00: This type of
notification turned off
0xFF: This type of notification turned on
Sensor Binary Report of 0x00
Sensor Type: 0xFF
1
Yes via Configuration Command Class
Parameter Number: 2