02.12.2022 Rev. 12
3. BURNER’S GENERAL FEATURES
ECOSTAR Dual Fuel (Gas-Light Oil) burners are designed and manufactured to work with liquid
fuel with max. 2.5- 6 Cst (mm
2
/
s) viscosity. and Natural Gas and Liquid Petroleum Gas at gas pressures
of min.20 mbar, max.300 mbar and at -%15 to +%10 of nominal voltages, under environmental
temperature of max.60˚C with rated capacity and burner pressure ranges.
3.1. Purpose of Use and Work Limits of Burners
• This product works at any load value equivalent to its max. capacity or covered by its capacity
range;
- In hot water and steam boilers,
- In direct and indirect hot air generators,
- Industrial appliances operating at temperature below 600
0
C,
- -15
0
C…+60
0
C ambient temperature range,
- 1N 230 VAC/3N 380VAC /50 Hz feed voltage (-%15…+%10) values,
- Max. 95% relative humidity,
- In well-ventilated open and closed spaces compatible with protection class IP 40.
This device must never be operated with open flame!