ECTIVE
®
POWER INVERTER – MI-/TMI-SERIES
]
44
Please note!
Exclusion of liability
Damages caused by polarity reversal and short circuits are excluded from liability.
Self error correction
Symptom Possible reason Solution
Inverter does
not work
1. connection to
consumers cut off
2. battery voltage
to low
1. check battery connection
2. check charging status
acoustic signal
sounds
and red LED
flashes
possible undervolt-
age (see table)
1. check charging status of battery, charge if
necessary
2. check compatibility of battery cable, use
higher cross section if necessary
3. check if conductive parts (cables, pole
terminals, lugs) are damaged.
acoustic signal
sounds
and red LED
flashes
total undervoltage
(see table)
1. check charging status of battery, charge if
necessary
2. check compatibility of battery cable, use
higher cross section if necessary
3. check if conductive parts (cables, pole
terminals, lugs) are damaged
red LED
flashes
input voltage too
high (see table)
1. check voltage
2. check charging voltage of battery charger
3. check if there are unwanted voltage
sources
red LED
flashes
inverter overheated 1. check ventilation, if damaged, call support
2. check if ventilations slits are free
3. check if ambient air is cool enough
4. reduce power