ECTIVE
®
SINUS/SINE INVERTER – CSI-/SSI-SERIES
]
46
Operating conditions
Everything at a glance
Power indication proportional to the
continuous output indicated in
120 % – 150 % for 10 seconds
150 % – 200 % for 2 seconds
Switching time UPS (both series) <16 ms
AC voltage 230 V
AC voltage fluctuation: max. 10%
Frequency: 50 Hz ± 1%
Waveform Pure sine wave (THD < 4%) at rated
input voltage
Battery types Wet, AGM, GEL, Li-Ion (only with BMS)
Idle current consumption charger CSI-series
Model 12 V 24 V 48 V
CSI30 approx. 0,35 A approx. 0,18 A approx. 0,09 A
CSI50 approx. 0,45 A approx. 0,23 A approx. 0,11 A
CSI100 approx. 0,53 A approx. 0,27 A approx. 0,13 A
CSI150 approx. 0,56 A approx. 0,28 A approx. 0,14 A
CSI200 approx. 0,63 A approx. 0,32 A approx. 0,16 A
CSI250 approx. 0,75 A approx. 0,38 A approx. 0,19 A
CSI300 approx. 0,85 A approx. 0,43 A approx. 0,21 A
CSI400 approx. 0,93 A approx. 0,47 A approx. 0,23 A