48 ECTIVE SI & TSI Series
Reason 12V 24V Action
risk of under-
voltage
10.8V±0.2V 21.6V±0.4V 2x acoustic signal + red LED flashing,
inverter still working
total undervol-
tage
10.2V±0.2V 20.4V±0.4V 3x acoustic signal + red LED flashing,
automatic inverter shutdown
overvoltage 15.5V±0.2V 31.0V±0.4V 4x acoustic signal + red LED flashing,
automatic inverter shutdown
overheating internal temperature
>75°C
5x acoustic signal + red LED flashing,
automatic inverter shutdown
overload due
to powerful
consumers
regardless of the type constant acoustic signal + red LED
flashing, automatic inverter shutdown
short circuit of
consumers
regardless of the type 11x acoustic signal + red LED on,
automatic inverter shutdown
polarity
reversal
SI 3 via fuse: the fuse blows
SI 5, SI 10, SI 15, SI 20,
SI 25, SI 30
TSI 5, TSI 10, TSI 15,
TSI 20, TSI 25, TSI 30
via MOSFET:
MOSFET cutoff
undervoltage
ECO-Mode
11V±0.2V 22V±0.4V shift to mains priority circuit
Please note!
Exclusion of liability
Damages caused by polarity reversal and short circuits are excluded from liability.