8 / 17
ET-RC remote controller
1. ON/OFF switch(press 3s),Backlight switch(press once)
2. LCD display
3. USB charging: 5VDC/2.1A * 2
About ET-RC remote cable
ET-RC remote cable is 13ft long standard RJ45 network cable,In order not to affect the display signal transmission, it is
recommended to use network lines within 16.5ft.
Note: If the remote controller can’t work properly, please try to replace the remote cable first.
8. SE RVICE ENVIRONMENT
Ambient temperature: -20~+50
Storage temperature: -40~+85
Relative humidity: 0~85% Non-condensing
9. NOTICE ABO UT MODIFIED SINE WAVE INVERTER
The output waveform of modified sine wave inverter is not pure sine wave, it is different from the waveform of our home
grid system. If you use it to run inductive loads, it is possible that the inverter can’t work properly, or its performance is
less than expected, this may also bring more noise.
1. If using a modified sine wave inverter, devices like induction cooker, coffee machine with pump or compressor inside,
medical equipment can’t work properly.
2. Motor, pump, electric saw, and devices with compressor, when starting, they may require 3-7 times power as their
rated power. It is not recommended to use a modified sine wave inverter to run these devices. If a modified sine wave
inverter is used, maybe these devices can’t start, this will also shorten the inverter’s life.
3. Fluorescent lamp (with Ballast), NiMH battery charger, it is not recommended to use a modified sine wave inverter for
long time, this devices will bring more noise with modified sine wave inverter. If using for long time, this will also
shorten the inverter’s life.