Manual drainage
When the portable air conditioner is in cooling or dry mode, it will dehumidify the
air. The water dehumidified from the air will be collected in an internal reservoir.
This water will be used to help cool the compressor and it will be evaporated and
exhausted out the exhaust hose. This unit is designed to exhaust most or all
condensate water collected out of the air, but in very humid conditions, the internal
reservoir may fill completely. This causes the air conditioner to turn off to avoid
overflowing the internal reservoir. The portable air conditioner will begin beeping
and the Run light will begin blinking and/or the display will show the E7 code. Drain
the unit to return to normal operation.
Drain parts:
1. Drain (there is a rubber plug inside this hole)
2. Drain cap
3. Drain hose
4. Drain tray
Draining with the drain tray
1. Make sure the unit is off.
2. Position the drain tray on the floor beneath the drain.
3. Unscrew the drain cap from the drain. Remove the rubber plug from the drain.
4. When the drain tray is almost full, insert the rubber plug back into the drain and
screw the drain cap back onto the drain.
16

Other manuals for EdgeStar AP410HS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EdgeStar AP410HS and is the answer not in the manual?

EdgeStar AP410HS Specifications

General IconGeneral
BrandEdgeStar
ModelAP410HS
CategoryAir Conditioner
LanguageEnglish

Related product manuals