EasyManuals Logo

EdgeStar AP8000W Service Manual

EdgeStar AP8000W
13 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
8
5 Modes and Operating Conditions
5.1 Terms and Definitions
TA: Ambient indoor temperature.
TS: Set temperature.
5.2 Cooling Mode (Blue Light)
The cooling temperature can be set from 61 to 89 (16 to 32.)
The timer function works in cooling mode.
The compressor will run when the difference between the set temperature and the actual ambient
room temperature conforms to the chart below:
When TA≤TS (for 1 minute) the compressor turns off.
When TA>TS+2 the compressor turns on.
5.3 Fan Only Mode (Green Light)
If the temperature can’t be controlled by the selected mode and the room ambient temperature is
shown on the display the unit will default to fan only mode.
The readout can only display a temperature of 32 to 99 (0 to 37.) lf the temperature is out of that
range the display will show LO or HI.
The Timer function works in fan only mode.
(TA-Ts)
+2
0
Operation conditon
compressor off with a delay of 1 minute
compressor on

Other manuals for EdgeStar AP8000W

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EdgeStar AP8000W and is the answer not in the manual?

EdgeStar AP8000W Specifications

General IconGeneral
Description of productPortable Air Conditioner
ModelAP8000W
ColorWhite
Voltage/FrequencyAC 115V~60Hz
Input Power840W
Current7.9A
Dehumidifying capacity71 Pints/Day
Timer24 Hour
CoolantR-410A
Weight and Dimensions IconWeight and Dimensions
Dimensions WxHxD19 1/4” 24 3/4” x13 1/4”
Weight56 lbs